Network Monitoring
Requirements:
- Must have the ability to monitor several private networks, each of which may be monitored by its own server, or possibly monitored by 1 primary server, with partitioned views.
- Must perform TCP level port monitoring - such as verifying that POP3 is active on an ISP server. Application layer monitoring - such as verifying POP3 authentication - is a plus.
- Must have good Cisco integration.
- Must monitor our video network, which includes:
- Sencore Receivers
- Motorola HD Encoders
- Tut Encoders (via the Tut EMS)
- Conklin Middleware severs
- Ineoquest
- Must monitor the Metaswitch (our 5E switch is not a requirement)
- Monitors Rectifiers, Heat Alarms, etc. via dry contacts
- Monitors existing Calix C7 equipment, and new E5 Calix equipment
- Monitors Adtran PRI/POTS devices
- Monitors SLAs - Can provide uptime information for customer services.
- Must be able to call on-call personal at night, via a direct POTS line phone connection.
- Should be able to provide restricted views to other personnel within the company, such as our trouble ticketing department.
- A (restricted) customer interface is a bonus - that is, providing an interface for customers to view outages, SLAs and interface statistics.
- Redundacy is also a requirement. We need to know if the monitoring system goes down.
Possible Solutions
- APC
- Applied Innovations
- Centina Systems
- Ciscoworks
- Cordell
- Dantel
- HP Openview
- OpenNMS
- Solarwinds
- Vaonet
- Zenoss
Dry Contact Boxes
http://www.asentria.com/products/ccu64.aspx
http://products.servertech.com/products/emcu-ip/
http://dataprobe.com/coe8_contacts_over_ethernet/index.html
http://www.fial.com/product_model.php?model=2311
http://www.phoenixbroadband.com/Product/ContactAgent/POU.htm
http://www.sinetica.co.uk/netcom.htm
http://www.sinetica.co.uk/mea.htm
http://www.uptimedevices.com/sensorhubs.php
http://www.apc.com/resource/include/techspec_index.cfm?base_sku=AP9340 ~$445.00
http://www.hw-group.com/products/ip_watchdog/index_lite_en.html
http://www.akcpinc.com/company/products.htm
http://www.wut.de/e-50www-10-inus-000.php
Devices to Monitor (Please Add)
- ACME Net-Net 4250
- ADC Kentrox IDSU (PTC)
- http://www.kentrox.com/Documentation/Product-Literature/Datasheet/DataSMART_MAX_T3-E3_IDSU_datasheet.aspx
- SNMP, but requires SLIP (Serial Line Internet Protocol)
- MIB located at http://www.oidview.com/mibs/181/DATASMART-MIB.html
- Adtran Netvanta 5305 (at PTC)
- http://www.adtran.com/web/page/portal/Adtran/product/4200990L1/118
- MIBs: http://www.adtran.com/adtranpx/Rooms/DisplayPages/LayoutInitial_webrQS_Q29udGFpbmVyPWNvbS53ZWJyaWRnZS5lbnRpdHkuRW50aXR5W09JRFs5MDUyMkY4MUQ5RUNDNDQ4ODNDQTg3OTA1MkYxOUIxOV1d
- Adtran Netvanta 3200 (CO T1 Box)
- Adtran TA9XX (FXO/FSX, i.e. Bixby School)
- Adtran MX2800 M13 Mux
- Adtran OPTI-6100
- APC PDU
- APC SmartUPS 3000
- http://www.apc.com/resource/include/techspec_index.cfm?base_sku=SUA3000RM2U&tab=models&total_watts=50
- Alarming??? Has DB9 RS-232, "Smartslot" and USB
- Avocent Autoview 3200 (KVM)
- Bitband
- http://www.bitband.com/Content.aspx?id=37
- "In addition, Vision servers support SNMP for remote management by standard third party tools."
- Calix C7
- Dry Contact Input: The Calix C7 supports provisioning of 8 user-defined alarms for ancillary equipment through wire wrap pins located on the shelf backplane's Alarm Interface Module (AIM).
- Dry Contact Output: The procedure below describes how to wire audible and visual alarms on the Calix C7 shelf to a central office alarm system. Use 26 AWG minimum (19 AWG maximum) wire. The C7 alarm contacts are Normally Open (default). The circuit closes when an alarm condition occurs.
- SNMP
- Calix E5
- Dry Contact Output
- SNMP
- Captaris Fax Server
- http://marketing.captaris.com/files/FaxPress/CaptarisFP_Admin_Guide.pdf
- Windows Event Log
- Cisco Gear:
- 3750
- 7606
- ASA5520
- 3640
- Aironet Access Points
- Cisco 4402 Wireless Controller
- MIBs located at http://www.cisco.com/public/mibs/
- Traps
- Various configuration changes
- authentication failure/success
- Link down/up
- Restart
- CPU Threshold
- Flash card insertion/removal
- Port Security http://en.wikipedia.org/wiki/802.1x
- Fan Alarm
- Power Supply Alarm
- Temperature Alarm
- Stack member change
- Routing Protocol Change (e.g. lost BGP neighbor)
- MAC changes/thresholds
- VLAN Membership
- Conference Bridge (?)
- Conklin Middleware
- Windows and Linux Servers
- Windows Event Log
- Syslog
- There may be some SNMP functionlity
- DASDEC EAS
- Dell Servers - BMC Backplane
- http://lonesysadmin.net/2005/09/23/configuring-and-securing-ipmi-on-dell-poweredge-x8xx-hardware/
- SNMP
- HP Procurve 2524 Switch
- Ineoquest IQTech Singulus
- International Data Casting Superflex DVB-S/DVB-S2
- Linux ISP Servers
- Service monitoring: pop3, imap, smtp, http, radius, ldap
- SNMP
- Lokbox
- Metaswitch
- Mitel Controller
- Motorola DSR-4400MD
- Motorola DSR-4402X
- Motorola DSR-4410MD
- http://www.amt.com/images/products//DSR4410MD_0807.pdf
- Ethernet/SNMP Monitoring and Control
- Motorola DSR-4500x
- Motorola SE-5100A
- Multitech Fax Server
- http://www.multitech.com/DOCUMENTS/Collateral/data_sheets/86002057.pdf
- None - other than basic ping polling.
- Netspan
- Packet Logic
- Patton 4114 - FXS/FXO at PTC and NO
- Redback
- http://www.redback.com/Redback/download/user/resource/SE400_DS_031309.pdf@SmartEdge%20400%20(472KB)
- SNMP
- Savin Printer
- http://www.savin.com/downloads/Default.aspx?hbn=manuals (See the CLP22 Software Guide)
- SNMP
- Scientific Atlanta Powerview D9850
- www.scientificatlanta.com/customers/source/7002752.pdf
- SNMP for setup, control and monitoring
- Scientific Atlanta Powervu D9828
- http://www.scientificatlanta.com/customers/source/7005872.pdf
- Dry-contact Alarm
- Scopus IRD-2900
- Sencore Atlas MRD 3187A
- Total Control Dial-in internet
- Tut
- 11 Shelves, with NMS/EMS server for monitoring
- TVN Catcher
- Valcom VIP (Paging for the School)
- http://www.valcom.com/techsupport/ip_solutions/techspecs/vip814ts.pdf
- Unknown - Basic ping polling
- VideoTek DDM-800
- Wegener Unity 4600
- http://www.wegener.com/PRODUCTS/UNITY/unity_4600_specs.php
- Ethernet/Serial for terminal control
- Alarm Relay
- Windows Servers
- SNMP
Count - Two year projection in Parentheses
- Acme Packet
- 2 (4)
- ADC Kentrox IDSU
- 1 (1)
- Adtran Netvanta 5305
- 1 (1)
- Adtran Netvanta 3200
- 1 (2)
- Adtran TA9XX
- 9 (25)
- Adtran M13 Mux
- 12 (15)
- Adtran OPTI-6100
- 1 (1)
- APC Power Devices
- 10 (20)
- Avocent Autoview 3200 (KVM)
- 3 (5)
- Bitband
- 2 (3)
- Calix
- C7 Shelves
- North Ring - 16 (16)
- North Ring #2 - 2 (4)
- South Ring - 16 (17)
- South Ring #2 - 12 (13)
- E5
- 400 - 8 (50)
- 110 - 15 (50)
- 120 - 15 (50)
- 121 - 5 (50)
- Captaris Fax Server
- 1 (1)
- Cisco
- 3750 - 25 (35)
- 7606 with 50GigE ports - 1 (2)
- 3640 - 2 (2)
- ASA - 4 (6)
- Aironet Wireless APs - 15 (20)
- Wireless Controller - 1 (2)
- Conference Bridge
- 1 (1)
- Conklin Middleware
- 12 (16)
- DASDEC EAS
- 1 (1)
- Dell Servers - BMC Backplane
- 18 (25)
- HP Procurve
- 12 (12)
- Ineoquest
- 4 (4)
- International Data Casting Superflex DVB-S/DVB-S2
- 9 (12)
- Linux ISP Servers
- 14 (18)
- Lokbox
- 1 (1)
- Metaswitch
- 1 (2)
- Mitel Controller
- 5 (7)
- Motorola DSR-4400MD
-
- Dry Contact: 16 (20)
- Motorola DSR-4402X
- Dry Contact: 11 (15)
- Motorola DSR-4410MD
- 1 (2)
- Motorola DSR 4500x
- 3 (5)
- Motorola SE-5100A
- 12 (15)
- Multitech Fax Server
- 1 (1)
- Netspan
- 1 (2)
- Packet Logic
- 1 (1)
- Patton 4114
- 14 (18)
- Redback SE-400
- 1 (1)
- Savin Printer
- 33 (33)
- Scientific Atlanta Powerview D9850
- 14 (18)
- Scientic Atlanta Powervu D9828
- 8 (11)
- Scopus
- 1 (2)
- Sencore Atlas MRD 3187A
- 5 (7)
- Total Control Dial-in
- 2 (2)
- Tut
- 11 (11)
- TVN Catcher
- 1 (1)
- Valcom VIP
- 7 (9)
- VideoTek DDM-800
- 1 (2)
- Wegener Unity 4600
- Dry Contact: 3 (4)
- Windows Servers
- 4 (8)
- Other
- Dry Contacts
- Invertors: 12 (14)
- Rectifiers: 20 (22)
- Fuse Panels: 22 (25)
- Generators: 9 (9)
- Fire Alarms: 10 (10)
- Intrusion Detection: 12 (12)
- Temperature Alarms: 10 (10)
- Future SNMP Devices: 0 (25)
- Current Number of SNMP Devices = 379
- Current Need for Dry Contact Alarming = 125
- Projected Number of SNMP Devices in 2 years = 668
- Projected Need for Dry Contact Alarming in 2 years = 142